P:\INSTALLATION INST\Mechanical Hardware\INST-S6800.vsd Rev - 12/10 Page 9
I. INSTALL BOTTOM STRIKE
1. Bore the hole into the finished floor or threshold (figure 9-1).
2. Install bottom strike into the hole (figure 9-2).
NOTE:
For flat thresholds the
clearance must be provided
in sill to accommodate full
9/16" (15mm) throw of latch
bolt.
1/4”
1/4”
Flat threshold application
(Panic device ONLY)
Strike application
J. INSTALL COVERS
1. Test push bar operation before installing covers;
a. No Trim: Latch bolts are retracted by the push
bar inside.
b. With Trim: Latch bolts are retracted by the push
bar inside, key or lever/knob outside.
c. Dogging: See dogging description and chart
page 10.
2. Check latch bolt engagement, adjust strikes
if required.
3. Install chassis cover over chassis assembly.
4. Install end cap.
2.441"
1.126"
1.850"
DOOR
(Top View)
C
L
of Bottom Latch
C
L
of Bottom Latch